News

Security policy for monitoring and management computer system in sluice gate

Publish Time: 2025-07-28
Very day security is an important work . How to keep anybody safety when they are working? How to guarantee dim runs smoothly and safely when sluice gate in remote control? 

Meixi’s monitoring and management computer system has been worked safely for more than twenty years ,  People in the office take control of sluice gate just by fingers while drinking a cup of tea. You can see each sluice gates through camera Video, and you can monitor sluice gate running data by management computer. Daily report was printed , also by monthly or year.

Why their system get so safely and stability? We have three security policies for monitoring and management computer system in sluice gate.

First is jam alarm testing, the system tests each gate when they are running, if they are slower or stop the system will alarm beep and stop quickly, the sluice gate is jam, alarm information turns out and tells officer to pay attention, checks gate more carefully if it is jam.

Second is distance limited . When the gate is opening or closing, the opening distance or the closing distance must be less than 120cm, if the distance is more than 120cm, the system will stop the gate and alarm. You see, when the sluice gate in auto control mode by monitoring and management computer system, the longest distance is 40cm , if the sluice gate is in auto control mode , the distance has never been more than 120cm, if this happened ,the sluice gate would be out of control . it must be stopped and alarm beep.

The third is timed limited. When the sluice gate gets to run , the clock is began to time, The timed limited is 30 seconds, you see each sluice gate’s opening or closing speed is 4cm/s, if it runs normally, 30s time will get 120cm distance,  if the sluice gate in auto control mode , the distance has never been more than 120cm, if this happened ,the sluice gate would be out of control. It must be stopped and alarm beep.

The sluice gate jam and distance limited are 3D space protection , the timed limited is 4D space protection, it looks the same , but it is different. When the gate detection or sensor is out of order, the distance is not more than 120cm . but the timed is more than 30s ,the monitoring and management computer system will stopped the gate and alarm , it is the lastly protection for remote control sluice gate.

Sometimes, operator started opening the gate in manual mode, but he forgot to stop the gate, the gate would go to the highest position of sluice gate , it is very dangerous for dim. But if you adopted the security policy for Monitoring and management computer system , when the gate distance is more than 120cm or the timed is more than 30s , the sluice gate should must be stopped  by the two limited policies. These security policy’s program protects  the  dim  safe all the time by automatic control system.

In some special cases ,operator wants to open sluice gate more than 400cm, the security policy limited is 120cm, How can I get it ? Good question! First, the system must be in manual mode, we can divide into four steps, each step is opening 100cm, and the system will not alarm, and you can open sluice gate at 400cm as quickly as possible.

Thanks you for reading these paper , if you need any help for security control of sluice gate , let me know, I will happy to assist.


×